Engineers designing AC/DC power systems, motor drives, and inverters need accurate, fast-responding current measurement without galvanic isolation complexity. The MLX91208LDC-CAL-000-SP delivers open-loop Hall-based current sensing with 250mV/mT sensitivity and programmable output calibration, enabling reliable detection across industrial and automotive applications. This sensor combines IMC-Hall® technology with broad bandwidth and thermal stability, though proper field-to-output mapping and temperature compensation are essential for consistent linearity.

MLX91208LDC-CAL-000-SP Melexis Technologies
The MLX91208LDC-CAL-000-SP is a monolithic open-loop Hall effect current sensor manufactured by Melexis Technologies NV, designed for surface-mount integration in SOIC-8 packaging. This specific variant operates across -40°C to 150°C and features a nominal sensitivity of 250mV/mT with a ±20mT operational field range (CAL-000 configuration). The sensor leverages Melexis's proprietary Integrated Magneto-Concentrator (IMC-Hall®) technology, which orients the Hall effect element parallel to the IC surface—allowing horizontal magnetic flux measurement suitable for PCB or bus-bar current sensing without active feedback loops.
Key operational parameters include DC to 200kHz bandwidth, 3μs typical response time, ratiometric voltage output (4.5–5.5V supply), and AEC-Q100 automotive qualification. The device integrates programmable sensitivity, offset, and temperature compensation through a programming interface, offering flexibility across current ranges from a few amperes to hundreds of amperes depending on magnetic circuit design.
IMC-Hall® Magneto-Concentrator Integration
Unlike conventional planar Hall sensors sensitive only to flux perpendicular to the IC surface, the MLX91208 incorporates an on-die integrated magnetic concentrator deposited as a back-end process step. This enables sensitivity to magnetic flux applied horizontally (parallel to the surface), making it ideal for current-carrying conductor proximity sensing on printed circuit boards or laminated bus bars.

MLX91208LDC-CAL-000-SP magnetic field orientation and PCB trace proximity sensing geometry
Broad Output Sensitivity Range
The CAL-000 configuration provides programmable sensitivity from 100 to 700mV/mT (nominal 250mV/mT). This wide programmability allows designers to scale output voltage for varying current ranges without redesigning the magnetic coupling. Resolution of 0.1% supports fine-tuned calibration during system commissioning.
Fast Response and High Bandwidth
Typical step response time of 2–3μs (with noise filter disabled) and nominal 200kHz bandwidth enable real-time current control in inverter, motor drive, and AC/DC converter applications where switching frequencies exceed 10kHz. When noise filtering is enabled, response extends to 5–9μs and bandwidth narrows to 120–180kHz—a tradeoff for EMI immunity in noisy switching environments.
Extended Temperature Operating Range
Qualified operation from -40°C to 150°C junction temperature with programmable temperature compensation (dual-slope for cold and hot regions, plus sensitivity temperature coefficient). This supports automotive underhood and industrial cabinet-mounted deployments without external heating or cooling.
Ratiometric Output Option
When enabled, output voltage scales proportionally with supply voltage, reducing sensitivity to PSU ripple and drift. This mode trades absolute accuracy for supply-rejection benefits, selectable via programmable configuration.
Bidirectional AC/DC Measurement
Full-scale output spans both positive and negative magnetic fields, supporting true alternating current and DC current direction detection without additional filtering or polarity management.
Inverter Current Monitoring
Inverter bridges require fast, accurate arm/phase current feedback for PWM control. The MLX91208's 3μs response time and 200kHz bandwidth align with high-frequency switching. Magnetic coupling via planar conductors or bus bars allows integration without PCB redesign. Programmable sensitivity matches typical 50–500A shunt ranges used in automotive and industrial inverters.
BLDC and Three-Phase Motor Drive Current Sensing
Motor control algorithms demand per-phase or dc-link current measurement for torque estimation, fault detection, and commutation timing. The sensor's open-loop nature eliminates delay and feedback-loop stability concerns. Ratiometric mode helps maintain consistent control margins across varying battery or supply voltages.
Smart Fuse and Over-Current Detection
Overcurrent protection circuits benefit from fast response and wide measurement range. Programmable offset allows threshold tuning; diagnostic self-checks detect sensor faults or magnetic saturation.
AC/DC Converter and Switched-Mode Power Supply Monitoring
Industrial PSUs and power factor correction stages use Hall sensors for input line current and output load feedback. The ±20mT field range (CAL-000) suits typical ferrite transformer and PCB trace couplings in 100–500W supplies.
HEV/EV Battery Management and Charging
Electric vehicle on-board chargers and battery management systems employ Hall sensors for charge/discharge current monitoring and fault isolation. The extended temperature range and automotive qualification enable reliable operation in vehicle harnesses and charging stations.
The MLX91208 is offered in multiple field-version options (xxL: 10mT, xxH: 25mT, xxV: 60mT). The CAL-000 suffix designates the high-field variant (25mT nominal range, ±25mT operational) with standard 250mV/mT nominal sensitivity. This pairing is critical for design compatibility.
Field Range and Saturation
Within the ±25mT operational field range, linearity error remains bounded at ±0.7% of full scale. Beyond ±25mT, the integrated magnetic concentrator progressively enters saturation, causing sharp linearity degradation. Applications exceeding this range require either lower-sensitivity versions (CAL-001 for 60mV/mT nominal on the very-high-field xxV variant) or redesign of the magnetic circuit to reduce flux density at the sensor.
Sensitivity-to-Current Conversion
Magnetic field density at the sensor depends on conductor geometry, current magnitude, and air-gap distance. For example, a straight PCB trace carrying 50A at 2mm distance produces approximately 2.5mT; a 500A bus bar at the same distance generates 25mT.

MLX91208LDC-CAL-000-SP magnetic field estimation: current, conductor geometry, and sensor spacing relationship
Designers must calculate expected field using Ampere's law or finite-element analysis to verify that peak currents remain within the ±25mT boundary.
Output Voltage Scaling
With 250mV/mT nominal sensitivity and 5V supply, the output rests at 2.5V (ratiometric midpoint) with zero external field. A +20mT input produces approximately 2.5V + (20 × 250mV/mT / 1000) = 7.5V, which exceeds the supply and indicates saturation/clipping at the output amplifier maximum (~97% VDD ≈ 4.85V). Proper magnetic coupling design must limit field excursions to ±10mT for linear operation within the full 10%–90% VDD output window (0.45V–4.55V).

MLX91208LDC-CAL-000-SP output voltage saturation and linearity limits within ±25mT field range
Programmable Sensitivity Trade-offs
Lower sensitivity values (100–200mV/mT) expand the usable output range for high fields; higher values (500–700mV/mT) improve resolution for low-current applications. Commissioning systems typically profile the actual magnetic field across the expected current range and select sensitivity to maximize output headroom while maintaining linearity.
Ratiometric Voltage Output
The MLX91208 outputs an analog voltage (10%–90% VDD range typical) proportional to sensed magnetic field. Ratiometric mode ties output scaling to the instantaneous supply voltage—reducing sensitivity to PSU jitter but introducing output impedance variation. Designers must account for a 1–5Ω output resistance and capacitive loading up to 10nF.
Load Impedance Constraints
Optimal linearity is achieved with resistive loads of 6kΩ or higher. Loads below 1kΩ degrade linearity; short-circuit protection prevents output damage but may mask design errors. Measurement circuits using high-impedance ADC inputs (or op-amp buffers with 10MΩ+ input Z) easily meet this requirement.
Response Time and Bandwidth Trade-offs
With noise filter disabled (default), 2–3μs response covers 200kHz bandwidth, suitable for fast PWM loops and switching-frequency ripple rejection. Enabling the digital noise filter extends response to 5–9μs and narrows bandwidth to 120–180kHz, trading speed for EMI robustness.

MLX91208LDC-CAL-000-SP bandwidth and response time trade-off: noise filter disabled vs. enabled
High-noise environments (adjacent switching converters, long PCB traces) may require the filter; real-time control loops (sub-microsecond latency) demand the filter-off configuration.
Supply Voltage Effects
Supply current ranges from 6–14mA (12mA typical at no load). Voltage excursions or noise on the VDD rail couple through internal regulators and can modulate output offset or gain. Clean, stable 4.5–5.5V rails with local 100nF and 10μF decoupling near the sensor are strongly recommended. Under-voltage detection (3.3V threshold, 0.2–0.45V hysteresis) triggers diagnostic flags; over-voltage detection (6.5–7.6V) similarly protects the device.
Temperature Coefficient and Drift
Typical sensitivity temperature coefficient is not explicitly listed in the datasheet but is programmable via dual-slope compensation (separate coefficients for -40 to 0°C and 0 to 150°C). Without active compensation, raw sensitivity drifts ±1–2% over the full range; offset drifts ±0.5–1.5% are common in Hall sensors. The MLX91208 integrates these trimming capabilities on-die (TC1ST, TC2ND_COLD, TC2ND_HOT parameters).
Commissioning Temperature Profile
Optimal accuracy across -40 to 150°C requires characterizing offset and sensitivity at three temperature points (e.g., -40°C, +25°C, +150°C) during system calibration. The programmable dual-slope model allows best-fit compensation; manufacturers typically pre-calibrate or provide temperature tables for standard configurations. Custom compensation may be necessary for applications demanding <±0.5% accuracy across the full range.
Offset Drift Programming
Offset temperature drift (OFFDR2C for cold, OFFDR2H for hot regions) independently adjusts the quiescent output voltage with temperature. This prevents zero-current errors from accumulating across the -40 to 150°C window, which is critical in precision current measurement or battery management systems.
Magnetic Circuit Design
The MLX91208 is sensitive to magnetic flux parallel to the IC surface. Hall plate position (shown in datasheet Section 18.3) must be aligned perpendicular to current-carrying conductors. For PCB traces, the sensor should be mounted adjacent (2–5mm gap) with current flowing beneath. For bus bars, placement within the magnetic field depression (formed by bar geometry) optimizes flux concentration. Finite-element magnetic modeling (FEA) is recommended for high-accuracy designs to predict field distribution and sensor placement.
Printed Circuit Board Layout
Keep VDD and GND traces short and use multiple vias for low inductance. Place a 100nF ceramic capacitor within 5mm of the sensor's VDD pin; add a 10μF bulk capacitor within 25mm. Route the analog output (OUT) away from switching signals and digital switching nodes to prevent capacitive coupling of dV/dt noise. If the sensor output feeds an ADC with analog multiplexing, include a local 10nF capacitor at the measurement node to stabilize the held voltage between samples.
Diagnostic and Fault Detection
The MLX91208 provides self-diagnostic flags (Section 12) for under-voltage, over-voltage, thermal issues, and magnetic saturation conditions. Monitor these status bits in firmware to detect sensor faults, PSU collapse, or design margin violations. Saturation detection (progressive linearity degradation beyond ±25mT) may indicate installation errors, insufficient air gap, or current magnitudes outside design specification.
Programming Interface
Sensitivity, offset, and temperature coefficients are programmable via a serial interface (details in Section 11, Programming Through Connector). Factory calibration or first-power commissioning typically stores these values in on-die EEPROM. Reprogramming after field deployment requires specific tools or firmware routines; plan for one-time calibration during manufacturing or integration.
Comparison with Other Melexis Field Versions
Melexis offers three field-version options for the MLX91208 base model:
| Aspect | CAL-000 (xxH, 25mT) | CAL-001 (xxV, 60mT) | CAV-000 (xxL, 10mT) |
|---|---|---|---|
| Nominal Field Range | ±20 mT | ±50 mT | ±7.5 mT |
| Operational Field Range | ±25 mT | ±60 mT | ±10 mT |
| Nominal Sensitivity (std) | 250 mV/mT | 60 mV/mT (CAV-001) | 250 mV/mT (CAV-000) |
| Programmable Sensitivity | 100–700 mV/mT | 30–200 mV/mT | 100–700 mV/mT |
| Linearity (within range) | ±0.7 % FS | ±0.7 % FS | ±0.7 % FS |
| Typical Use Case | Medium-current (50–300A) industrial/automotive | High-current (200–1000A) industrial power | Low-current (<50A) precision systems |
The CAL-000 (this product) is the balanced choice for typical automotive inverters, motor controllers, and industrial PSUs operating in the 100–500A range. Upgrading to CAL-001 (xxV) requires accepting lower output sensitivity (narrower voltage swings) but tolerates 2.4× higher field density—useful for compact or high-current designs. Downgrading to CAV-000 (xxL) increases sensitivity but limits field range, suitable only for distributed or auxiliary current sensing circuits.

MLX91208LDC-CAL-000-SP field-version comparison matrix: CAL-000, CAL-001, and CAV-000 operational ranges and sensitivity
The MLX91208LDC-CAL-000-SP combines proven IMC-Hall® magnetic sensing with automotive-grade reliability and programmable output calibration, making it a solid choice for open-loop current measurement in power electronics, motor drives, and EV charging systems. The ±25mT operational field range and 250mV/mT nominal sensitivity are well-matched to typical 50–500A current ranges with standard PCB and bus-bar geometries. Success requires careful magnetic circuit design to verify field density remains within range, proper PCB layout to manage supply decoupling and output noise, and commissioning-time temperature calibration to achieve specified accuracy across -40 to 150°C. Verify that your application's peak magnetic field excursion does not exceed ±25mT; if it does, consider the CAL-001 high-field variant or reassess the sensor-to-conductor coupling geometry.