A resettable fuse is an overcurrent protection device that increases its resistance when excessive current generates heat. Most resettable fuses use polymeric positive temperature coefficient (PPTC) technology. After the fault clears, the PPTC resets when power is removed or reduced enough for it to cool. Unlike conventional fuses, PPTCs limit current rather than completely disconnecting the circuit. This article explains their working principles, key specifications, applications, and practical selection methods.

Figure 1. Radial-Leaded PPTC Resettable Fuses for Overcurrent Protection
A resettable fuse is a current-sensitive protection component that changes from a low-resistance state to a high-resistance state during an overcurrent event. The term usually refers to a PPTC device, also called a polyfuse. PolySwitch and Multifuse are product trademarks used by Littelfuse and Bourns, respectively.
A PPTC is installed in series with the circuit it protects. Under normal conditions, it conducts load current with a relatively small voltage drop. When sufficient electrical heating causes it to trip, its resistance rises sharply and reduces current through the load. The device generally returns toward its original state after power is removed and it cools.
PPTCs operate passively, need no control signal, and are offered in surface-mount, radial-lead, and battery-strap formats. Their principal advantage is recovery from suitable overloads without routine component replacement.
The word "fuse" can be misleading. A tripped PPTC still conducts residual current and dissipates power. Its response also depends on temperature and fault duration. It is therefore unsuitable wherever a design requires a guaranteed open circuit or precisely controlled current cutoff without additional protection.
A typical PPTC contains conductive particles dispersed through a semi-crystalline polymer. At normal temperature, contacts between particles form conductive networks through the material. This produces the low resistance required for ordinary operation.
As the polymer approaches its transition region, its structure changes and it expands. Particle connections separate, causing a steep increase in resistance. The effect is reversible to a useful degree, although the resistance after recovery is not necessarily identical to the original value.

Figure 2. Internal Structure and Tripping Mechanism of a PPTC Fuse
Current flowing through the device generates heat according to:
where I is the current through the PPTC and R is its instantaneous resistance. At normal current, heat transferred to the board and surrounding air balances heat generation, keeping the device in its low-resistance state.
Thermal conditions are part of its operation, not merely an installation detail. Identical PPTCs on different PCB layouts can reach different temperatures at the same current.
During a sustained overload, increased heating raises the device temperature. Once the conductive network begins to separate, resistance climbs rapidly. The higher resistance shifts more of the supply voltage across the PPTC, reducing load current.
Tripping is not instantaneous. A high fault current heats the element faster than a mild overload. Starting temperature, available supply current, and heat transfer also influence the response. Consequently, there is no single trip delay that applies to every fault.
While the fault supply remains connected, residual current can generate enough heat to maintain the high-resistance, or latched, state. This depends on the circuit’s voltage, available current, and thermal balance.
After the fault clears, the PPTC resets when power is removed or reduced enough for it to cool. Its conductive network then reforms and resistance decreases, although recovered resistance need not equal its initial value.

Figure 3. PPTC Trip and Reset Sequence (Illustrative)
Hold current (IHOLD) is the maximum current the device is specified to carry without tripping under stated conditions. Trip current (ITRIP) is the minimum current specified to cause tripping under its stated test conditions. For example, the Littelfuse 1206L Series defines both at 20 °C in still air. The Low Rho temperature-rerating table gives reference hold currents at 20 °C. The electrical specifications table lists trip currents without stating their test temperature.
The region between them is not a guaranteed operating window. Whether a device eventually trips there depends on heating and the surrounding circuit. Compare the derated hold current with continuous load demand, rather than assuming the room-temperature value applies inside a warm enclosure.
VMAX is the maximum specified voltage the PPTC can withstand under the manufacturer’s stated rating conditions. IMAX is the maximum prospective fault current the device can withstand at its rated voltage. Neither rating implies that the PPTC fully disconnects the load.
Both checks matter. A part rated for adequate normal load current can still be unacceptable if a higher supply voltage or fault-current source exceeds its maximum ratings.
Datasheets distinguish RMIN, the minimum as-supplied resistance; RMAX, the maximum as-supplied resistance when specified; and R1MAX, the maximum resistance measured after a defined trip or soldering process and recovery interval. These values must be interpreted at the temperatures and conditions specified for the particular series.
For example, the Littelfuse 1206L Series datasheet explicitly defines R1MAX at 20 °C one hour after tripping or reflow soldering at 260 °C for 20 s. Littelfuse also provides corresponding 20 °C, one-hour post-trip or post-reflow guidance for Low Rho SMT PPTCs in an application note. The Low Rho series electrical table reports RMIN and R1MAX but no separate RMAX. These room-temperature values do not guarantee the maximum in-circuit resistance at higher temperatures.
Reference definitions: Littelfuse 1206L Series datasheet; Littelfuse Low Rho SMT application note
A time-current graph plots trip time against applied current, often on logarithmic axes. To read it, locate the expected fault current and follow it to the curve for the selected part. Read the corresponding trip time, then check whether the curve represents typical behavior or a guaranteed limit.
A datasheet may also specify a maximum time to trip at one particular test current. That value must not be applied to lower currents or other temperatures without supporting data. The protected traces, connectors, and components must tolerate the actual current until protection responds. The Low Rho examples in C6.5 list separate specified test points; they do not provide a continuous time-current curve.
Some datasheets specify PD as typical power dissipation in the tripped state. This value does not represent the device’s normal-state power rating or replace thermal verification.
Higher ambient temperatures generally reduce hold and trip currents, while lower temperatures increase them. Manufacturer derating tables provide the appropriate current ratings for different temperatures. PCB copper area, airflow, enclosure temperature, and nearby heat sources also affect the device’s thermal performance.

Figure 4. Temperature Derating of PPTC Hold Current
| Feature | PPTC Resettable Fuse | Conventional Fuse | Electronic Fuse (eFuse) |
| Fault response | High resistance; residual current remains | Opens circuit within voltage and breaking-capacity ratings | Current limiting or electronic shutdown (part-dependent) |
| Recovery | After the fault clears, the PPTC resets when power is removed or reduced enough for it to cool. | Replacement required | Auto-retry or latch-off, where supported |
| Response control | Thermal, current-dependent | Defined time-current behavior | Control response depends on the selected IC |
| Additional functions | No active diagnostics | No active diagnostics | Device-dependent monitoring and fault functions |
| Main trade-off | Residual current and temperature sensitivity | One-time operation | Supply requirements and greater complexity |
A conventional fuse opens when sufficient overcurrent melts its element. Check the fuse's time-current curve, voltage rating, and breaking capacity against the circuit conditions. This makes a conventional fuse preferable when a fault must interrupt current and disable equipment until inspection.
A PPTC instead raises its resistance and limits sustained fault current without guaranteeing isolation. Select either device using its time-current response and the actual prospective fault current.
An eFuse uses semiconductor switching and control circuitry to provide current limiting or electronic shutdown, depending on the IC. Supported fault-handling options include auto-retry or latch-off. Individual devices may also control inrush, report faults, or provide overvoltage and reverse-current protection; check the selected datasheet rather than assuming these functions are universal.
PPTCs provide straightforward passive current limiting. eFuses are appropriate when the application requires electronically controlled fault response, diagnostics, or configurable recovery behavior.
A thermal cutoff opens in response to temperature and is generally a one-time device. A ceramic PTC thermistor shares positive-temperature-coefficient behavior but differs in material and characteristics. Circuit breakers use mechanical contacts and can interrupt and reset under their specified ratings. These devices are not interchangeable solely because they respond to abnormal current or heat.
PPTCs are used in USB power paths and peripheral equipment to limit sustained overload current. The main concerns are continuous port current, connector and trace ratings, normal-state voltage drop, and startup transients. The current limit demanded by a USB power-delivery design may require an active protection switch rather than a thermal PPTC alone.
Battery-strap and low-resistance PPTCs provide an additional protection element in appropriate battery assemblies. Low resistance helps preserve runtime, while package shape and thermal contact influence trip behavior. A PPTC does not replace the battery-management functions needed for overcharge, undervoltage, cell-temperature monitoring, or cell balancing.
Selected PPTC families protect sensors, controllers, and low-voltage auxiliary circuits. Here, temperature range, vibration, surge exposure, and qualification are important. Use products specifically documented for the environment. Automotive qualification is not implied by a generic PPTC listing.
Specialized telecom PPTCs help limit overcurrent from abnormal line conditions, usually alongside surge-protection components. For motors, prolonged stall current can produce enough heating to trip a properly selected PPTC. Startup current and repeated stall events must be tested so normal acceleration does not trigger unwanted protection.
Record the maximum continuous load current, full supply-voltage range, ambient and local board temperatures, startup waveform, and prospective fault current. Establish the maximum allowable fault duration that traces and components can safely withstand. Without that protection-time requirement, selecting a current rating does not establish that the circuit is protected.
Select a PPTC whose derated hold current at the highest local ambient temperature exceeds the maximum continuous load current. Read the manufacturer’s part-specific temperature table; do not assume all PPTCs share the same derating percentage. Check that normal heating and any nearby heat sources do not erase the margin.
Compare the highest credible voltage across the device with VMAX. Include supply tolerance and relevant fault conditions, not just the nominal rail voltage. Determine the maximum prospective short-circuit current from the power source and upstream impedance, then verify it is within IMAX under the specified voltage conditions.
Use the time-current curve or a defined maximum trip-time value at the relevant test current. Examine both sustained overloads and brief inrush pulses.
Determine the lowest sustained fault current at the minimum operating temperature. Compare it with the applicable trip-current characteristics, accounting for temperature dependence. Verify that the PPTC reaches its protective state before downstream components exceed their allowable stress. If the manufacturer does not provide sufficient trip data, confirm the response through testing.
Separately estimate the series voltage drop and loss:
Use a resistance value appropriate to the measurement conditions. Room-temperature post-trip resistance does not by itself bound the resistance of a hot, installed device.
Consider an illustrative 5 V power rail supplying up to 2.0 A continuously, with a maximum local ambient temperature of 60°C. Assume the highest supply voltage is 5.25 V and the prospective fault current is 30 A. These are design assumptions for the example—not manufacturer-specified USB requirements or measured properties of a real system.
A preliminary candidate is Littelfuse 1206L400/12SL, from the Low Rho Series datasheet. Its published values include:
| Parameter | 1206L400/12SL | 1206L300/12SL |
| IHOLD at 20°C | 4.0 A | 3.0 A |
| Reference IHOLD at 60°C | 2.4 A | 2.0 A |
| ITRIP at 20°C | 8.0 A | 6.0 A |
| VMAX | 12 V | 12 V |
| IMAX | 50 A | 50 A |
| RMIN | 0.003 Ω | 0.003 Ω |
| R1MAX | 0.016 Ω | 0.030 Ω |
| Maximum time to trip (specified test current) | 2.0 s maximum at 20 A | 4.0 s maximum at 8 A |
At 60°C, the 1206L300/12SL has a reference hold current of 2.0 A, equal to the maximum load current, leaving no nominal current margin. The 1206L400/12SL provides 2.4 A, giving a 0.4 A margin, or 20% relative to the load current. It also has a lower specified R1MAX. Both devices meet the preliminary voltage and maximum fault-current checks. The 1206L400/12SL is therefore the stronger candidate for normal-load operation, although its response to lower-level faults still requires verification.
For a resistance-based screening calculation at 2.0 A, using the published 0.016 Ω R1MAX gives:
Using the published R1MAX of 0.016 Ω as a post-reflow, 20°C screening reference gives a voltage drop of 32 mV and a power loss of 64 mW at 2.0 A. These calculations do not establish the maximum resistance or power loss at the 60°C application temperature.
The datasheet’s 2.0 s maximum trip-time specification applies at 20 A, not at every overload current. It cannot be used to claim that the device protects against a 3 A or 5 A fault within two seconds, nor does it establish a guaranteed response at 60°C.
Selection result: the part passes an initial current, voltage, and fault-rating screen. It is not yet a validated final choice. Protection during lower-level overloads, startup immunity, hot-board resistance, and the allowable damage time still require measurements or additional manufacturer data.
PPTCs are available in surface-mount (SMD), radial-leaded, and battery-strap packages. SMD devices support automated PCB assembly, radial-leaded types use through-hole mounting, and battery-strap versions accommodate suitable battery connections.
Select the package according to available space, mounting requirements, and assembly methods. Check the manufacturer’s recommended footprint, soldering profile, and post-reflow resistance specifications. PCB copper area and nearby heat sources also require consideration because they influence device temperature and trip behavior.
If a PPTC trips during normal startup, check the inrush current caused by input capacitors or motor acceleration. Record the current waveform and compare its magnitude and duration with the device’s time-to-trip characteristics. If normal startup exceeds the device’s thermal tolerance, consider an alternative PPTC rating or an inrush-control circuit.
If a PPTC does not trip during an overload, measure the sustained fault current and local temperature. Compare the results with the applicable hold and trip characteristics, especially at low ambient temperatures. A prolonged overload can damage downstream components even when the PPTC remains conductive. If the device cannot limit the fault current within the required time, use a more suitable protection device.
If the PPTC remains in its high-resistance state, check whether the supply continues delivering residual current. Disconnect power, remove the fault, and allow the device to cool. Measure its resistance after the specified recovery period. If normal operation does not resume, inspect the load for persistent faults and the PPTC for permanent damage.
If voltage drop increases after repeated trips or assembly, compare resistance measurements under consistent temperature and recovery conditions. Check the soldering process, nearby heat sources, and PCB copper layout. Determine whether the measured resistance remains within the manufacturer’s specified limits.
Exceeding a PPTC’s voltage, fault-current, or temperature ratings can cause permanent damage, overheating, or loss of protection. The Littelfuse Low Rho series is intended for occasional overcurrent or overtemperature faults; its datasheet cautions against applications with anticipated repeated faults or prolonged trip events. Check the exact part’s endurance data before assuming frequent or sustained tripped operation is acceptable.
The Low Rho devices are UL Recognized Components under the applicable component program; this does not mean the finished product has received UL certification. AEC-Q200 qualification, where explicitly specified for an automotive-grade part, concerns component stress testing rather than end-equipment safety approval. Verify the exact model’s UL/TÜV/CSA status and the applicable end-equipment requirements separately.
Source: Littelfuse Low Rho Series datasheet, Warning section
Validate the selected PPTC on the final PCB under realistic operating conditions. Measure voltage drop and device temperature at maximum load, then test startup, sustained overload, and short-circuit conditions across the required temperature range.
Record fault current and trip response to confirm that downstream components remain within their allowable limits. Repeat trip-and-recovery cycles and measure resistance after the specified recovery period. For safety-regulated products, complete the applicable equipment-level abnormal-operation and single-fault tests.
A PPTC resettable fuse provides passive, recoverable current limiting, but it does not isolate a faulted circuit. Good selection requires more than matching IHOLD to load current: temperature derating, maximum fault ratings, resistance, and trip time must meet the circuit’s needs. The datasheet narrows candidate parts. Board-level testing confirms the protection response. When complete interruption is needed, choose a conventional fuse with suitable voltage and breaking-capacity ratings. Where adjustable current limiting or electronic shutdown is required, an eFuse can provide auto-retry or latch-off, depending on the part.